Anemometer
Anemometer
Adaptive and highly sensitive sensor with fast response and high accuracy.
● CFM/CMM Thermo-anemometer with built-in non-contact IR thermometer measures remote surface temperature to 280ºC (536ºF) and 8:1 distance to spot ratio.
● Simultaneous display of air flow or air velocity plus ambient temperature.
● Easy to set area dimensions (cm2) are stored in the meter´s internal memory for the next power on it.
● Resolution of 0.01m/sec.
● 20 Points average for air flow.
● 3% Velocity accuracy via low friction 2.83"D (72mm) ball bearing vane wheel on 3.9ft (120cm) cable.
● Large LCD display, reliable & stable.
● Accessories: instruction manual, vane sensor with 3.9ft (120cm) cable, 9V battery, protective rubber holster and carrying case.
|
0 . 8 to 58 . 0 knots |
0. 9 to 67 . 0 MPH |
1. 4 to 108 . 0 k m / h |
0.4 0 to 30. 0 m/ s |
80 to 5.900 ft / min |
Range |
Air Velocity |
|
0.1 knots |
0.1 MPH |
0.1 k m / h |
0.1 m/ s |
1 ft / min |
Resolution |
|
|
± (3%rdg +0.4 knots) |
± (3% rdg + 0.4MPH) |
± (3% rdg + 0.8km/h) |
± (3% rdg + 0. 20m/s) |
± (3% rdg+40 ft/m) |
Accuracy |
|
|
0 to 999999 m³ / min ( 0.1) |
Air flow CMM ( Res . ) |
|||||
|
0 to 999999 ft ³ / min ( 0.1 ) |
Air flow CFM ( Res . ) |
|||||
|
0 to 999 . 9 m ² |
Area CMM |
|||||
|
0 to 999. 9 ft ² |
Arae CFM |
|||||
|
-10 to 60 ° C ( 14 to 140 ° F ) ( 0 . 1 ° C / F ) |
Air Temperature ( Res . ) |
|||||
|
2 ° C ( 4 ° F ) |
Accuracy Air Temperature |
|||||
|
- 50 to 260 ° C ( - 58 to 500 ° F ) ( 1 ° C / F ) |
Infrared Temperature ( Res . ) |
|||||
|
- 50 to -20 ° C ( - 58 to -4 ° F ) : ± 5 ° C ( 9 ° F ) - 20 to 260 ° C ( - 4 to 500 ° F ) : ± 2 % reading or ± 2 ° C ( 4 ° F ) whichever is greater |
||||||
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Anemometer
Adaptive and highly sensitive sensor with fast response and high accuracy.
● CFM/CMM Thermo-anemometer with built-in non-contact IR thermometer measures remote surface temperature to 280ºC (536ºF) and 8:1 distance to spot ratio.
● Simultaneous display of air flow or air velocity plus ambient temperature.
● Easy to set area dimensions (cm2) are stored in the meter´s internal memory for the next power on it.
● Resolution of 0.01m/sec.
● 20 Points average for air flow.
● 3% Velocity accuracy via low friction 2.83"D (72mm) ball bearing vane wheel on 3.9ft (120cm) cable.
● Large LCD display, reliable & stable.
● Accessories: instruction manual, vane sensor with 3.9ft (120cm) cable, 9V battery, protective rubber holster and carrying case.
|
0 . 8 to 58 . 0 knots |
0. 9 to 67 . 0 MPH |
1. 4 to 108 . 0 k m / h |
0.4 0 to 30. 0 m/ s |
80 to 5.900 ft / min |
Range |
Air Velocity |
|
0.1 knots |
0.1 MPH |
0.1 k m / h |
0.1 m/ s |
1 ft / min |
Resolution |
|
|
± (3%rdg +0.4 knots) |
± (3% rdg + 0.4MPH) |
± (3% rdg + 0.8km/h) |
± (3% rdg + 0. 20m/s) |
± (3% rdg+40 ft/m) |
Accuracy |
|
|
0 to 999999 m³ / min ( 0.1) |
Air flow CMM ( Res . ) |
|||||
|
0 to 999999 ft ³ / min ( 0.1 ) |
Air flow CFM ( Res . ) |
|||||
|
0 to 999 . 9 m ² |
Area CMM |
|||||
|
0 to 999. 9 ft ² |
Arae CFM |
|||||
|
-10 to 60 ° C ( 14 to 140 ° F ) ( 0 . 1 ° C / F ) |
Air Temperature ( Res . ) |
|||||
|
2 ° C ( 4 ° F ) |
Accuracy Air Temperature |
|||||
|
- 50 to 260 ° C ( - 58 to 500 ° F ) ( 1 ° C / F ) |
Infrared Temperature ( Res . ) |
|||||
|
- 50 to -20 ° C ( - 58 to -4 ° F ) : ± 5 ° C ( 9 ° F ) - 20 to 260 ° C ( - 4 to 500 ° F ) : ± 2 % reading or ± 2 ° C ( 4 ° F ) whichever is greater |
||||||