India Table Top Sieve Shaker for Pharma Industries – Includes 6 Brass Sieves & 1 Collection Pan | Laboratory Testing Instrument
Die sieve shakers work on the principle of vibration, agitation, or gyration. In order to effectively use sieve shakers for screening, data on particle size distribution, sieve load, sieve shaking method, particle shape and size, and ratio of sieve open area to total area must be considered. Sieving can be affected by powder properties like friability and cohesion. In sieving, the sample is either horizontally or vertically moved, depending on the technology. The particles and sieve are moved around during this movement. Depending on the size of the particles, a particle flows through the sieve mesh or stays on the mesh surface. The likelihood of a particle passing through the mesh openings depends on factors such as particle size, particle orientation, and the number of times the particle comes in contact with the mesh openings. So, the sieving is influenced by the sieving time and the sieve movement.
Sieve shakers consist of a base, a cradle for holding sieves, and an electrical power unit. The figure illustrates the cradle, which is constructed from two vertical rods joined at the lower ends by a platform. There is a horizontal support that can pivot freely around the higher ends that are shock-mounted. Holding the top bar securely against the nest of sieves are sieve holders, retainer rings, and nuts on the vertical support rods. The sieves used are standard sieves with varying sieve numbers.
Working Arrangement of sieves in a nest is done with the coarsest at the top. On the top sieve, a sample of the powder is placed. For a certain period of time, this sieve set is shaken for 20 minutes with the mechanical shaker apparatus. Each sieve is weighed after it has been shaken. Uses Materials of all kinds are tested for particle size using sieve shakers. The machine can handle a maximum of 150 m of coarse material. For wet sieve analysis, the material analyzed does not come into contact with the liquid except to be dispersed. Merits It is easy to operate a sieve shaker. Samples are separated in a short time. Only particles with a diameter up to 50 mm can be used. Installation takes up less space. It is possible to accurately and reproducibly size particles. Compared with other methods, this instrument has a lower cost.
Original: $205.85
-70%$205.85
$61.75Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Die sieve shakers work on the principle of vibration, agitation, or gyration. In order to effectively use sieve shakers for screening, data on particle size distribution, sieve load, sieve shaking method, particle shape and size, and ratio of sieve open area to total area must be considered. Sieving can be affected by powder properties like friability and cohesion. In sieving, the sample is either horizontally or vertically moved, depending on the technology. The particles and sieve are moved around during this movement. Depending on the size of the particles, a particle flows through the sieve mesh or stays on the mesh surface. The likelihood of a particle passing through the mesh openings depends on factors such as particle size, particle orientation, and the number of times the particle comes in contact with the mesh openings. So, the sieving is influenced by the sieving time and the sieve movement.
Sieve shakers consist of a base, a cradle for holding sieves, and an electrical power unit. The figure illustrates the cradle, which is constructed from two vertical rods joined at the lower ends by a platform. There is a horizontal support that can pivot freely around the higher ends that are shock-mounted. Holding the top bar securely against the nest of sieves are sieve holders, retainer rings, and nuts on the vertical support rods. The sieves used are standard sieves with varying sieve numbers.
Working Arrangement of sieves in a nest is done with the coarsest at the top. On the top sieve, a sample of the powder is placed. For a certain period of time, this sieve set is shaken for 20 minutes with the mechanical shaker apparatus. Each sieve is weighed after it has been shaken. Uses Materials of all kinds are tested for particle size using sieve shakers. The machine can handle a maximum of 150 m of coarse material. For wet sieve analysis, the material analyzed does not come into contact with the liquid except to be dispersed. Merits It is easy to operate a sieve shaker. Samples are separated in a short time. Only particles with a diameter up to 50 mm can be used. Installation takes up less space. It is possible to accurately and reproducibly size particles. Compared with other methods, this instrument has a lower cost.