Microprocessor Based Water & Soil Analysis Kit (8 Parameters)
Soil Analysis Kit
It is used for the measurement of pH, Conductivity, TDS, Salinity, Temperature, Dissolved Oxygen, ORP (mV), Turbidity 16x2 Alphanumeric LCD Display with backlit, Rechargeable battery cum mains operated with all accessories, In-Built Battery Charger, Storage upto 700 samples, external printer attachment facility and fitted in briefcase.
TECHNICAL SPECIFICATIONS:
|
pH
Range : 0-14 pH
Resolution : 0.01pH
Accuracy : + 0.01 pH ( relative)
Temp. Comp. : Automatic with Pt100 Sensor
&Manual by keys
Buffer Recognition : 4.00 , 7.00 , 9.20 ( Automatic)
Calibration : Automatic & Manual
: 2 Point, 3 Point(Prog.)
|
Dissolved Oxygen
Range : 0 to 20 ppm
Resolution : 0. 1 ppm
Calibration : Automatic
Accuracy : + 0.2 ppm + 1digit
Temp. Comp. : Automatic with Pt100 Sensor &
Manual By keys
Pressure comp. : 0-999 mm of Hg ( Manual)
Salinity Correction : 0-20 mg/l
|
|
mv/ORP
Range : - 1999 to +1999 mV
Resolution : 1 mV
Calibration : Manual
Accuracy : + 0.1% + 1digit
|
Temperature
Range : -20.0 to +200 degree C
Resolution : 0.1 degree C
Accuracy : + 0.2% + 1digit
Input : Pt100
Calibration : Manual
|
|
Conductivity
Range : 0-1000 mS/cm
Range Selection : Automatic
Resolution : 0.01/ 0.1/ 1 uS/cm or mS/cm as
per range
No. of Ranges : Six
Accuracy : + 0.5%
Temp. Comp. : Automatic with Pt100 Sensor
Ref. Temp. : 25 degree C/20 degree C(Prog.)
Temp. Co-efficient : 0-4% adjustable
Cell constant : 0.05 to 2.0 adjustable
|
TDS
Range : 0-200ppt in 5-ranges Automatic
Resolution : 0.01/0.1/1 ppm or ppt as per range
Temp. Comp. : Automatic
Accuracy : + 0.5%
TDS Factor : 0.50 by default(adjustable)
Cell constant : 0.05 to 2.0 adjustable
Ref. Temp. : 25 degree C/20 degree C(Prog.)
|
|
Turbidity
Range : 0-1000 NTU in Two Ranges
Resolution : .1 NTU in lowest Range
Range Selection : Automatic
Accuracy : ±3% FS±1-digit
Detector : Photodiode/Photocell
Sample System : 30 mm Clear Glass test tube
Light Source : 6V Tungsten Lamp
Calibration : Manual
|
|
|
Salinity
Range : 0-200ppt in 5-ranges Automatic
Resolution : 0.01/0.1/1 ppm or ppt as per
range
Temp. Comp. : Automatic
Accuracy : + 0.5%
Salinity factor : 0.75 by default( adjustable)
Cell constant : 0.05 to 2.0 adjustable
Ref. Temp. : 25 degree C/20 degree C(Prog.)
|
General
Display : 16 characters X 2 lines alpha
Numeric BL LCD
Display format : Temp. and parameter
Simultaneously
Real Time Display : 24 Hour Mode With Date &
Time
Controls : By soft keys Menu Driven
Storage : Up to 1000 samples
Power Supply : 230 V +10 % 50 Hz & Inbuilt 12 V Rechargeable battery
Digital Output : Serial RS-232
: Parallel Centronics
Print format : All Data
: Date Wise (Programmable) Error Indication : pH Error,ORP Error,T-Error
|
|
Data Interface:
RS232 & Parallel output available for interfacing to computer/printer
|
|
|
Accessories
1. pH electrode 2. Buffer solutions
3. Conductivity/TDS/Salinity Cell 4. Temp. probe
5. DO probe, DO membranes, KCL 6. Operation manual 7. ORP Electrode AT EXTRA COST 8. Test Tubes
|
Original: $467.85
-70%$467.85
$140.35Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Soil Analysis Kit
It is used for the measurement of pH, Conductivity, TDS, Salinity, Temperature, Dissolved Oxygen, ORP (mV), Turbidity 16x2 Alphanumeric LCD Display with backlit, Rechargeable battery cum mains operated with all accessories, In-Built Battery Charger, Storage upto 700 samples, external printer attachment facility and fitted in briefcase.
TECHNICAL SPECIFICATIONS:
|
pH
Range : 0-14 pH
Resolution : 0.01pH
Accuracy : + 0.01 pH ( relative)
Temp. Comp. : Automatic with Pt100 Sensor
&Manual by keys
Buffer Recognition : 4.00 , 7.00 , 9.20 ( Automatic)
Calibration : Automatic & Manual
: 2 Point, 3 Point(Prog.)
|
Dissolved Oxygen
Range : 0 to 20 ppm
Resolution : 0. 1 ppm
Calibration : Automatic
Accuracy : + 0.2 ppm + 1digit
Temp. Comp. : Automatic with Pt100 Sensor &
Manual By keys
Pressure comp. : 0-999 mm of Hg ( Manual)
Salinity Correction : 0-20 mg/l
|
|
mv/ORP
Range : - 1999 to +1999 mV
Resolution : 1 mV
Calibration : Manual
Accuracy : + 0.1% + 1digit
|
Temperature
Range : -20.0 to +200 degree C
Resolution : 0.1 degree C
Accuracy : + 0.2% + 1digit
Input : Pt100
Calibration : Manual
|
|
Conductivity
Range : 0-1000 mS/cm
Range Selection : Automatic
Resolution : 0.01/ 0.1/ 1 uS/cm or mS/cm as
per range
No. of Ranges : Six
Accuracy : + 0.5%
Temp. Comp. : Automatic with Pt100 Sensor
Ref. Temp. : 25 degree C/20 degree C(Prog.)
Temp. Co-efficient : 0-4% adjustable
Cell constant : 0.05 to 2.0 adjustable
|
TDS
Range : 0-200ppt in 5-ranges Automatic
Resolution : 0.01/0.1/1 ppm or ppt as per range
Temp. Comp. : Automatic
Accuracy : + 0.5%
TDS Factor : 0.50 by default(adjustable)
Cell constant : 0.05 to 2.0 adjustable
Ref. Temp. : 25 degree C/20 degree C(Prog.)
|
|
Turbidity
Range : 0-1000 NTU in Two Ranges
Resolution : .1 NTU in lowest Range
Range Selection : Automatic
Accuracy : ±3% FS±1-digit
Detector : Photodiode/Photocell
Sample System : 30 mm Clear Glass test tube
Light Source : 6V Tungsten Lamp
Calibration : Manual
|
|
|
Salinity
Range : 0-200ppt in 5-ranges Automatic
Resolution : 0.01/0.1/1 ppm or ppt as per
range
Temp. Comp. : Automatic
Accuracy : + 0.5%
Salinity factor : 0.75 by default( adjustable)
Cell constant : 0.05 to 2.0 adjustable
Ref. Temp. : 25 degree C/20 degree C(Prog.)
|
General
Display : 16 characters X 2 lines alpha
Numeric BL LCD
Display format : Temp. and parameter
Simultaneously
Real Time Display : 24 Hour Mode With Date &
Time
Controls : By soft keys Menu Driven
Storage : Up to 1000 samples
Power Supply : 230 V +10 % 50 Hz & Inbuilt 12 V Rechargeable battery
Digital Output : Serial RS-232
: Parallel Centronics
Print format : All Data
: Date Wise (Programmable) Error Indication : pH Error,ORP Error,T-Error
|
|
Data Interface:
RS232 & Parallel output available for interfacing to computer/printer
|
|
|
Accessories
1. pH electrode 2. Buffer solutions
3. Conductivity/TDS/Salinity Cell 4. Temp. probe
5. DO probe, DO membranes, KCL 6. Operation manual 7. ORP Electrode AT EXTRA COST 8. Test Tubes
|