Microprocessor Flame Photometer (Na, K, Ca, Li)

Product image 1

Microprocessor Flame Photometer (Na, K, Ca, Li)

flame photometer price

Microprocessor Flame Photometers 1600-G comes with Flame Failure detection and Auto Gas Cutoff Facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after a few seconds.

Microprocessor Flame Photometer 1600-G is used for the determination of Sodium, Potassium, Calcium, Lithium & Barium. They use the latest microcontroller technology and advanced engineering techniques to give enhanced accuracy and reproducibility. They have soft touch membrane keys for ease of operation.

The results are displayed on the 128 x 64 Graphical LCD with Backlit. The standard model comes with 2 filters (Na, K). Additional filters Ca & Li are optional at extra cost.

 

In this model, Calibration can be done with up to 25 standards of user choice (5 point for each element) and non-linearity correction is provided through an automatic curve fitting software. Multiple Calibration Curves can be stored in the memory. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of multiple standards once a calibration has been performed.

Salient Features:                                                                                     

 

·              Microprocessor Based with Printer Interface                                                              

 

·              Auto Gas Cutoff  Facility                                                                                            

 

·              Auto Flame Failure Detection                                                                           

 

·              Five Measurements in Single Aspiration of the sample

 

·              Calibration Curve Programmability Using Maximum of 25 Standard

 

·              Data Processing Through Curve Fitting Techniques- Least Squares, Quadratic

 

·              Multiple Calibration Curves Saving Facility

 

·              Printer Attachment Facility

 

·              Measurement can be done in ppm as well as in meq                                         

 

·              Setup Storage Facility (up to 10 setup files)                                                               

 

·              Sample Data Storage Facility                                                                            

 

·              Direct Results in ppm and meq. 

 

·              Online Help key                                                             

 

·              Useful for both Medical & Soil Testing Applications

 

 

MODE

 

General

 

Serum (in meq/l)

 

Urine (in meq/l)

 

ppm                                   

 

meq/l

 

RANGE

 

Na

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

K

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

Ca

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

Li

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

Ba

 

:

 

50-1000

 

 

 

0 – 200  1:100 dil.

 

0 – 10    1:100 dil.

 

 

0 – 2      1:5 dil.

 

 

0 – 250   1:100 dil.

 

0 – 100   1:100 dil.

 

0 – 10     1:2 dil.

 

 

 

Sensitivity

 

General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm, Ba: 50 ppm

 

Filters

 

Na & K supplied {Ca, Li and Ba are optional at extra cost and can be factory fitted only}

 

Resolution

 

0.1 ppm/0.1 meq

 

Reproducibility

 

< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as                                             maximum standard

 

Linearity

 

< 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard

 

Curve Fit Accuracy

 

< 2% of FS

 

Display

 

128x64 Alphanumeric LCD with backlit

 

Average Time

 

In-built in software

 

Flame System

 

LPG and Dry Oil Free Air

 

Detector

 

Silicon Photodiode

 

Calibration

 

With up to 25 Standards of User Choice with Curve Fitting Software (5 for Each Element) Multiple Calibration Curves can be stored in the memory

 

Gas Control

 

Adjustable with knobs

 

Flame Failure

 

Auto Detection

 

Gas Cutoff

 

Automatic

 

Ignition System

 

Auto Ignition

 

Atomizer

 

 

$210.53

Original: $701.78

-70%
Microprocessor Flame Photometer (Na, K, Ca, Li)

$701.78

$210.53

Product Information

Shipping & Returns

Description

flame photometer price

Microprocessor Flame Photometers 1600-G comes with Flame Failure detection and Auto Gas Cutoff Facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after a few seconds.

Microprocessor Flame Photometer 1600-G is used for the determination of Sodium, Potassium, Calcium, Lithium & Barium. They use the latest microcontroller technology and advanced engineering techniques to give enhanced accuracy and reproducibility. They have soft touch membrane keys for ease of operation.

The results are displayed on the 128 x 64 Graphical LCD with Backlit. The standard model comes with 2 filters (Na, K). Additional filters Ca & Li are optional at extra cost.

 

In this model, Calibration can be done with up to 25 standards of user choice (5 point for each element) and non-linearity correction is provided through an automatic curve fitting software. Multiple Calibration Curves can be stored in the memory. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of multiple standards once a calibration has been performed.

Salient Features:                                                                                     

 

·              Microprocessor Based with Printer Interface                                                              

 

·              Auto Gas Cutoff  Facility                                                                                            

 

·              Auto Flame Failure Detection                                                                           

 

·              Five Measurements in Single Aspiration of the sample

 

·              Calibration Curve Programmability Using Maximum of 25 Standard

 

·              Data Processing Through Curve Fitting Techniques- Least Squares, Quadratic

 

·              Multiple Calibration Curves Saving Facility

 

·              Printer Attachment Facility

 

·              Measurement can be done in ppm as well as in meq                                         

 

·              Setup Storage Facility (up to 10 setup files)                                                               

 

·              Sample Data Storage Facility                                                                            

 

·              Direct Results in ppm and meq. 

 

·              Online Help key                                                             

 

·              Useful for both Medical & Soil Testing Applications

 

 

MODE

 

General

 

Serum (in meq/l)

 

Urine (in meq/l)

 

ppm                                   

 

meq/l

 

RANGE

 

Na

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

K

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

Ca

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

Li

 

:

 

0-100

 

Upto 250 meq/l, 1:100 dil.

 

Ba

 

:

 

50-1000

 

 

 

0 – 200  1:100 dil.

 

0 – 10    1:100 dil.

 

 

0 – 2      1:5 dil.

 

 

0 – 250   1:100 dil.

 

0 – 100   1:100 dil.

 

0 – 10     1:2 dil.

 

 

 

Sensitivity

 

General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm, Ba: 50 ppm

 

Filters

 

Na & K supplied {Ca, Li and Ba are optional at extra cost and can be factory fitted only}

 

Resolution

 

0.1 ppm/0.1 meq

 

Reproducibility

 

< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as                                             maximum standard

 

Linearity

 

< 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard

 

Curve Fit Accuracy

 

< 2% of FS

 

Display

 

128x64 Alphanumeric LCD with backlit

 

Average Time

 

In-built in software

 

Flame System

 

LPG and Dry Oil Free Air

 

Detector

 

Silicon Photodiode

 

Calibration

 

With up to 25 Standards of User Choice with Curve Fitting Software (5 for Each Element) Multiple Calibration Curves can be stored in the memory

 

Gas Control

 

Adjustable with knobs

 

Flame Failure

 

Auto Detection

 

Gas Cutoff

 

Automatic

 

Ignition System

 

Auto Ignition

 

Atomizer

 

 

You may also like

-70%NEW
Thumbnail 1

Binocular microscope LED Light

$75.92

$22.78

-70%NEW
Thumbnail 1

Binocular Microscope WF10X Pair with Cover

$71.24

$21.37

-70%NEW
Thumbnail 1

Autoclave 12*15 Aluminium

$65.92

$19.78

NEW
Thumbnail 1

Autoclave machine 12*15 Stainless Steel

$79.75

-70%NEW
Thumbnail 1

Autoclave Horizontal High Pressure

$1,701.28

$510.38

-70%NEW
Thumbnail 1

Automatic Tissue Processor Unit

$1,275.96

$382.79

-70%NEW
Thumbnail 1

Autoclave Horizontal High Pressure Fully Automatically

$2,658.25

$797.48

-70%NEW
Thumbnail 1

Portable Autoclave

$63.48

$19.04

NEW
Thumbnail 1Thumbnail 2

SCIFA Benchtop Centrifuge Machine

$15.51

-70%NEW
Thumbnail 1

Biological Safety Cabinet

$691.14

$207.34

-70%NEW
Thumbnail 1

Bio-Chemistry Analyzer

$3,072.94

$921.88

-70%NEW
Thumbnail 1

Bar Breaking Apparatus

$17.01

$5.10