These compact and durable water distillation units are designed for easy wall mounting in laboratories, providing a reliable and economical solution for producing high-purity distilled water. Constructed from 304 grade stainless steel sheets, they ensure long service life, resistance to corrosion, and ease of cleaning.

The units are fitted with Kanthal A1 wire heating elements, known for their high efficiency, durability, and consistent performance. They are widely used in schools, colleges, research laboratories, and industries where distilled water of reliable quality is required.


Features

  • Wall-mounted design saves space in the laboratory.
  • Fabricated from SS 304 grade stainless steel for durability.
  • Fitted with Kanthal A1 heating elements for efficient and long-lasting heating.
  • Available in multiple output capacities (2, 4, 6, and 10 liters per hour).
  • Low maintenance and economical operation.
  • Provides consistent supply of high-quality distilled water.

Technical Specifications

Model

WMD2

WMD4

WMD6

WMD10

Output

2 LPH

4 LPH

6 LPH

10 LPH

Wattage

1.5 kW

3 kW

4.5 kW

6 kW

Heater

Kanthal A1 Wire

Kanthal A1 Wire

Kanthal A1 Wire

Kanthal A1 Wire

MOC

Stainless Steel 304

Stainless Steel 304

Stainless Steel 304

Stainless Steel 304

Power Supply

220V, 50 Hz

220V, 50 Hz

220V, 50 Hz

220V, 50 Hz


Applications

  • School and college laboratories
  • Research institutes
  • Pharmaceutical and chemical laboratories
  • Industrial testing laboratories
  • Hospitals and medical facilities

The Wall Mounted Stainless Steel Water Distillation Unit is the most economical and durable choice for laboratories in India, combining efficiency, reliability, and affordability.


Would you like me to also prepare a professional operating manual (installation, operation, safety, and maintenance instructions) for this water distiller, similar to the analytical balance manual I created?

1. Safety Instructions

  • Install the unit on a stable wall surface near a reliable water source and power supply.
  • Use only potable water as feed water. Avoid saline or hard water to prevent scaling.
  • Ensure proper electrical earthing before connecting power.
  • Do not touch the body or heating chamber during operation (surface may be hot).
  • Never operate the unit without sufficient feed water.
  • Switch OFF and allow to cool before cleaning or servicing.

2. Installation

  1. Unpack the unit carefully.
  2. Mount the unit securely on the laboratory wall using appropriate fasteners.
  3. Connect the water inlet to a clean water supply using standard tubing.
  4. Ensure the drain outlet is connected to a safe drainage point.
  5. Connect the power cord to a 220V, 50 Hz supply with proper earthing.
  6. Check that the unit is firmly mounted and all connections are leak-free.

3. Controls & Components

  • Water Inlet Connection – For raw water supply.
  • Distilled Water Outlet – Collects purified water.
  • Drain Outlet – For waste water and impurities.
  • Power Switch – Turns heating element ON/OFF.
  • Heating Chamber – Fitted with Kanthal A1 wire heating element.
  • Stainless Steel Body (SS 304) – Corrosion-resistant and durable.

4. Operating Instructions

4.1 Starting the Unit

  1. Ensure proper water supply is connected and valve is open.
  2. Check that the distilled water outlet container is clean.
  3. Switch ON the power supply.
  4. Heating will begin and distillation starts within a few minutes.
  5. Collect distilled water from the outlet into a sterile container.

4.2 During Operation

  • Ensure continuous water flow during use.
  • Do not allow the boiling chamber to run dry.
  • Avoid collecting the first 5–10 minutes of distillate for best purity.

4.3 Shutting Down

  1. Switch OFF the power supply.
  2. Close the water inlet valve.
  3. Allow the unit to cool before draining or cleaning.

5. Maintenance

  • Daily: Drain leftover water after each use to prevent scaling.
  • Weekly: Clean the boiling chamber with a soft cloth.
  • Monthly: Descale using mild acid (e.g., 5% dilute HCl), rinse thoroughly before reuse.
  • Annually: Inspect electrical connections and heating element. Replace if necessary.

6. Troubleshooting

Issue

Possible Cause

Solution

No distillate output

No water supply / Power OFF

Check water and power connections

Low distillate output

Scaling inside chamber

Clean and descale boiling chamber

Water leakage

Loose pipe connection

Tighten inlet/outlet connections

Overheating

Insufficient water flow

Ensure proper continuous water supply

Burnt heater

Dry running without water

Replace heater; always ensure water flow


7. Warranty & Service

  • Covered under LABPRO standard warranty against manufacturing defects.
  • Warranty excludes scaling damage, heater burnout due to dry running, or improper installation.
  • For service and spare parts, contact LABPRO Customer Support with model and serial number.

 

 

$52.10
Water Distillation Unit For Laboratory Price
$52.10

Product Information

Shipping & Returns

Description

Water Distillation Unit For Laboratory Price

These compact and durable water distillation units are designed for easy wall mounting in laboratories, providing a reliable and economical solution for producing high-purity distilled water. Constructed from 304 grade stainless steel sheets, they ensure long service life, resistance to corrosion, and ease of cleaning.

The units are fitted with Kanthal A1 wire heating elements, known for their high efficiency, durability, and consistent performance. They are widely used in schools, colleges, research laboratories, and industries where distilled water of reliable quality is required.


Features

  • Wall-mounted design saves space in the laboratory.
  • Fabricated from SS 304 grade stainless steel for durability.
  • Fitted with Kanthal A1 heating elements for efficient and long-lasting heating.
  • Available in multiple output capacities (2, 4, 6, and 10 liters per hour).
  • Low maintenance and economical operation.
  • Provides consistent supply of high-quality distilled water.

Technical Specifications

Model

WMD2

WMD4

WMD6

WMD10

Output

2 LPH

4 LPH

6 LPH

10 LPH

Wattage

1.5 kW

3 kW

4.5 kW

6 kW

Heater

Kanthal A1 Wire

Kanthal A1 Wire

Kanthal A1 Wire

Kanthal A1 Wire

MOC

Stainless Steel 304

Stainless Steel 304

Stainless Steel 304

Stainless Steel 304

Power Supply

220V, 50 Hz

220V, 50 Hz

220V, 50 Hz

220V, 50 Hz


Applications

  • School and college laboratories
  • Research institutes
  • Pharmaceutical and chemical laboratories
  • Industrial testing laboratories
  • Hospitals and medical facilities

The Wall Mounted Stainless Steel Water Distillation Unit is the most economical and durable choice for laboratories in India, combining efficiency, reliability, and affordability.


Would you like me to also prepare a professional operating manual (installation, operation, safety, and maintenance instructions) for this water distiller, similar to the analytical balance manual I created?

1. Safety Instructions

  • Install the unit on a stable wall surface near a reliable water source and power supply.
  • Use only potable water as feed water. Avoid saline or hard water to prevent scaling.
  • Ensure proper electrical earthing before connecting power.
  • Do not touch the body or heating chamber during operation (surface may be hot).
  • Never operate the unit without sufficient feed water.
  • Switch OFF and allow to cool before cleaning or servicing.

2. Installation

  1. Unpack the unit carefully.
  2. Mount the unit securely on the laboratory wall using appropriate fasteners.
  3. Connect the water inlet to a clean water supply using standard tubing.
  4. Ensure the drain outlet is connected to a safe drainage point.
  5. Connect the power cord to a 220V, 50 Hz supply with proper earthing.
  6. Check that the unit is firmly mounted and all connections are leak-free.

3. Controls & Components

  • Water Inlet Connection – For raw water supply.
  • Distilled Water Outlet – Collects purified water.
  • Drain Outlet – For waste water and impurities.
  • Power Switch – Turns heating element ON/OFF.
  • Heating Chamber – Fitted with Kanthal A1 wire heating element.
  • Stainless Steel Body (SS 304) – Corrosion-resistant and durable.

4. Operating Instructions

4.1 Starting the Unit

  1. Ensure proper water supply is connected and valve is open.
  2. Check that the distilled water outlet container is clean.
  3. Switch ON the power supply.
  4. Heating will begin and distillation starts within a few minutes.
  5. Collect distilled water from the outlet into a sterile container.

4.2 During Operation

  • Ensure continuous water flow during use.
  • Do not allow the boiling chamber to run dry.
  • Avoid collecting the first 5–10 minutes of distillate for best purity.

4.3 Shutting Down

  1. Switch OFF the power supply.
  2. Close the water inlet valve.
  3. Allow the unit to cool before draining or cleaning.

5. Maintenance

  • Daily: Drain leftover water after each use to prevent scaling.
  • Weekly: Clean the boiling chamber with a soft cloth.
  • Monthly: Descale using mild acid (e.g., 5% dilute HCl), rinse thoroughly before reuse.
  • Annually: Inspect electrical connections and heating element. Replace if necessary.

6. Troubleshooting

Issue

Possible Cause

Solution

No distillate output

No water supply / Power OFF

Check water and power connections

Low distillate output

Scaling inside chamber

Clean and descale boiling chamber

Water leakage

Loose pipe connection

Tighten inlet/outlet connections

Overheating

Insufficient water flow

Ensure proper continuous water supply

Burnt heater

Dry running without water

Replace heater; always ensure water flow


7. Warranty & Service

  • Covered under LABPRO standard warranty against manufacturing defects.
  • Warranty excludes scaling damage, heater burnout due to dry running, or improper installation.
  • For service and spare parts, contact LABPRO Customer Support with model and serial number.